Looking to download the right firmware for your PTZOptics camera?
PT12X-SDI/NDI-xx
PT12X-USB-xx
PT20X-SDI/NDI-xx
PT20X-USB-xx
PT30X-SDI/NDI-xx
PTVL-ZCAM/NDI-ZCAM
PT12X-ZCAM/NDI-ZCAM
PT20X-ZCAM/NDI-ZCAM
PTEPTZ-ZCAM/NDI-ZCAM
PT-WEBCAM-80
PT-JOY-G4
PT-SUPERJOY-G1
PT12X-SDI/NDI-xx
6/21/2022 – SOC ver 6.3.62
- Added Exposure Compensation to Exposure options AAE & SAE
- Added Backlight to Exposure options AAE & SAE
- Added MIDI Control (For notes on how to configure MIDI Camera Control, read the MIDI Guide available here)
- Change the Max Bit Rate to 102,400 kbps
5/3/2022 – SOC ver 6.3.56
- Fixed an bug with HTTP-CGI Direct Position Recall commands failing
2/19/2022 – SOC ver 6.3.50
- Added the ability to save unique OSD settings per preset
- Added a VISCA over IP command to enable/disable RTMP streaming
- 81 0A 11 A8 pq FF – p: 1 Stream 1; p: 2 stream 2; q: 2 ON, q: 3 OFF
- Added a VISCA over IP inquiry command to query if the camera is RTMP streaming (81 09 11 53 FF)
- Added support for a HTTPS certificate file
- Added a VISCA over IP command to Freeze/Unfreeze the video feed
- 81 01 04 62 0p FF – p: 2 ON; p: 3 OFF
- Updated the camera’s web interface & available options
- The camera’s Standby light will now be illuminated when it’s set to Standby mode via the VISCA over IP command
- NTP Time Zones now support half time zones
- SRT now supports domain name mode. Default is set to Off
- Fixed a Zoom Speed bug
8/19/2021 – SOC ver 6.3.34 (PoE)
- Increased camera security parameters
- Once this firmware is applied, presets will be stored in on-board memory, allowing the presets to remain after future firmware updates, without requiring the backup/restore function.
- Added IR address buttons to the camera’s Web Interface under “System”
- Changed the IR remote shortcut ([*] > [#] > [4]: Show camera IP address) to display the information until manually closed with the ‘Home’ button
- Removed “Auto Scan Shoot” from the camera’s OSD menu and replaced it with “Auto Inspect”. Auto Inspect will call every camera preset, in order, on repeat.
- When “Auto Inspect” is enabled, you can adjust the “Residence Time” (How long the camera will remain at a preset). Range: 1 – 60 (seconds)
- When “Auto Inspect” is enabled, you can adjust “Call Preset Speed” (How fast the camera calls each preset). Range: 1 – 24.
- Removed “Auto Focus L” from the camera’s OSD menu due to limited space in “Setup”
- Added the ability to start and stop RTMP streams without requiring a power cycle
- Added a “privacy function” that points the camera to the rear when set to Standby
3/31/2021 – SOC ver 6.3.29 (PoE)
- Support for NDIv4|HX
- Support for NDI Discovery Server
- Support for Windows, Mac, and Custom NTP address
- Support for Variable Latency parameters of SRT
- Changed default OSD Timeout to “Off”
- Changed camera RTSP stream 2 output to “MJPEG” when NDI Preset is set to “Off” (This allows view of the camera feed within the Web Interface’s “Live” tab)
- DHCP bug fixes
12/15/2020 – SOC ver 6.3.12 (PoE)
- Supports Sony VISCA over IP
- Supports SRT
- Default Preset Recall Speed changed to 12 from 24
- Solved network feed audio issues
- Supports network feed image freeze (requires cam restart)
- Corrected some VISCA & VISCA over IP command responses
- DHCP bug fixes
- Added Pan/Tilt Limit Reset to OSD Menu
- Default Image Style changed from ‘Default’ to ‘Clarity’
8/4/2020 – SOC ver 6.2.97 (PoE)
- Supports CAM_OtherBlockInq VISCA over IP command
- Fixed OSD & Inquiry bug with sharpness settings
- Added commands for RG / BG Tuning in VAR White Balance mode
- Added support for focal range
- Added VISCA, VISCA over IP, and HTTP-CGI commands to adjust focal range
- Added OSD Timeout to OSD menu within Settings
- OnePush Auto Focus VISCA, VISCA over IP, & HTTP-CGI command
10/4/2019 – SOC ver 6.2.82 (PoE)
- PanTilt LimitSet Bugfix
- Supports Multi-Language
- Supports RTMPS
- Photobooth Functionality
- Improved i-Frame range
- Improved Port range
- Supports New IR Remote IP Address Set shortcuts
- [#] + [*] + [#] + [1]: Sets IP Address to 192.168.100.81
- [#] + [*] + [#] + [2]: Sets IP Address to 192.168.100.82
- [#] + [*] + [#] + [3]: Sets IP Address to 192.168.100.83
- [#] + [*] + [#] + [4]: Sets IP Address to 192.168.100.84
- [#] + [*] + [#] + [5]: Sets IP Address to 192.168.100.85
- [#] + [*] + [#] + [6]: Sets IP Address to 192.168.100.86
- [#] + [*] + [#] + [7]: Sets IP Address to 192.168.100.87
- [#] + [*] + [#] + [8]: Sets IP Address to 192.168.100.88
- [#] + [*] + [#] + [9]: Sets IP Address to 192.168.100.89
- [#] + [*] + [#] + [0]: Sets IP Address to 192.168.100.80
5/22/2019 – SOC ver 7.2.60 (Non PoE) SOC ver 6.2.73 (PoE)
- WebUI S/N
- NTP synchronization
- Assignable UDP port
- Remove assignable VISCA Addr in WebUI
- ONVIF Login Fix
- Web Server Security Update
- Multicast default address 234.1.2.88
- P/T Reset Command
- PTZ Motion Sync (Experimental)
- CORS
- HTTP-CGI Direct Zoom with Speed
- PanTilt_LimitSet via VISCA over IP
- I/F Clear Command
- Backup and Save As
- HOME position proper ack / response
5/30/2018 – SOC ver 6.2.50 (PoE)
- Resolves camera reset from heavy network traffic
1/18/2018 – SOC ver 6.2.40 (PoE)
- Improved NDI compatibility
- Improved VISCA over IP control
- Bug fixes
1/17/2018 – SOC ver 6.2.39 (PoE & non-PoE)
- Camera is now “NDI Ready”
- Presets 1-9 include focus
- Video within web interface enabled in Internet Explorer (ActiveX driver needed from downloads page)
- Web interface now affects OSD Menu Settings
- New IR Remote shortcut for DHCP: [#]+[*]+[4]
- Removed “D-HotPixel” from Noise Reduction in OSD
- Added “Auto Scan Shoot” in OSD Menu
6/16/2017 – SOC ver 7.2.23 (PoE & non-PoE)
- Improved performance with PT-JOY/PT-JOY-G2
- Bug fixes
PT12X-USB-xx
9/13/2021 – SOC ver 6.2.81
- Support for SRT functionality
- Support for Windows, Mac, and Custom NTP address
- Changed default image style from Clarity to Default
- Added Pan/Tilt Limit Reset to OSD Menu
- Solved network feed audio issues
- Resolved bug when calling presets while in AutoFocus mode
- Resolved bug when querying camera’s brightness level
- Assorted bugfixes
12/15/2020 – SOC ver 6.2.70
- General bugfixes and compatibility updates
- Added OSD Timeout to OSD menu within Settings
- Default Preset Recall Speed changed to 12 from 24
- Default Image Style changed from ‘Default’ to ‘Clarity’
8/4/2020 – SOC ver 6.2.66
- Increased UVC protocol commands
- Supports Red & Blue fine tune inquiry command
- Added sharpness & auto sharpness modes
- Bugfixes to focus & ARM
- Removed Motion Sync minimum speed
2/5/2020 – SOC ver 6.2.59
- UVC bugfixes
- PanTilt_LimitSet bugfix while mirrored
- Added more IR remote shortcuts
- [#] + [*] + [#] + [1]: Sets IP Address to 192.168.100.81
- [#] + [*] + [#] + [2]: Sets IP Address to 192.168.100.82
- [#] + [*] + [#] + [3]: Sets IP Address to 192.168.100.83
- [#] + [*] + [#] + [4]: Sets IP Address to 192.168.100.84
- [#] + [*] + [#] + [5]: Sets IP Address to 192.168.100.85
- [#] + [*] + [#] + [6]: Sets IP Address to 192.168.100.86
- [#] + [*] + [#] + [7]: Sets IP Address to 192.168.100.87
- [#] + [*] + [#] + [8]: Sets IP Address to 192.168.100.88
- [#] + [*] + [#] + [9]: Sets IP Address to 192.168.100.89
- [#] + [*] + [#] + [0]: Sets IP Address to 192.168.100.80
10/4/2019 – SOC ver 6.2.56
- Photobooth Functionality
- Support Serial Number through Web Interface
- Improved i-Frame range
- Improved Port range
- Supports RTSP password Authentication
- Supports RTMPS
- Corrected “Home” VISCA over IP command
5/22/2019 – SOC ver 6.2.52
- WebUI S/N
- NTP Synchronization
- Assignable UDP Port
- Remove assignable VISCA Addr in WebUI
- ONVIF Login Fix
- Multicast default address 234.1.2.88
- P/T Reset Command
- PTZ Motion Sync (Experimental)
- CORS
- HTTP-CGI Direct Zoom with Speed
- PanTilt_LimitSet via VISCA over IP
- I/F Clear Command
- Backup and Save As
- HOME position proper ack / response
- OSD Option & VISCA command to disable USB Audio
- 81 2a 02 a0 04 0p ff p=2: on, p=3: off
- 81 2a 02 a0 04 ff Query USB Audio
- 90 50 03 ff = off
- 90 50 02 ff = on
5/4/2018 – SOC ver 6.2.39
- Camera is now “NDI Ready”
- Presets 1-9 include focus
- Video within web interface enabled in Internet Explorer (ActiveX driver needed from downloads page)
- Web interface now affects OSD Menu Settings
- New IR Remote shortcut for DHCP: [#]+[*]+[4]
- Removed “D-HotPixel” from Noise Reduction in OSD
- Added “Auto Scan Shoot” in OSD Menu
6/16/2017 – SOC ver 6.2.23
- Improved performance with PT-JOY/PT-JOY-G2
- Bug fixes
PT20X-SDI/NDI-xx
6/21/2022 – SOC ver 6.3.22
- Added Exposure Compensation to Exposure options AAE & SAE
- Added Backlight to Exposure options AAE & SAE
- Added MIDI Control (For notes on how to configure MIDI Camera Control, read the MIDI Guide available here)
- Change the Max Bit Rate to 102,400 kbps
5/6/2022 – SOC ver 6.3.20
- Added the ability to save unique OSD settings per preset
- Added a VISCA over IP command to enable/disable RTMP streaming
- 81 0A 11 A8 pq FF – p: 1 Stream 1; p: 2 stream 2; q: 2 ON, q: 3 OFF
- Added a VISCA over IP inquiry command to query if the camera is RTMP streaming (81 09 11 53 FF)
- Added support for a HTTPS certificate file
- Added a VISCA over IP command to Freeze/Unfreeze the video feed
- 81 01 04 62 0p FF – p: 2 ON; p: 3 OFF
- Updated the camera’s web interface & available options
- The camera’s Standby light will now be illuminated when it’s set to Standby mode via the VISCA over IP command
- NTP Time Zones now support half time zones
- SRT now supports domain name mode. Default is set to Off
- Fixed a Zoom Speed bug
- Added support for additional HTTP-CGI commands
- http://[camera ip]/cgi-bin/param.cgi?post_image_value&wbmode&[mode]
- [mode] options: auto, indoor, outdoor, onepush, manual, var, trigger
- http://[camera ip]/cgi-bin/param.cgi?post_image_value&aemode&[mode]
- [mode] options: auto, manual, shutter, iris, bright
- http://[camera ip]/cgi-bin/param.cgi?post_image_value&wbmode&[mode]
- Fixed a bug when viewing the web interface using Safari
3/31/2021 – SOC ver 6.3.16 (PoE)
- Support for NDIv4|HX
- Support for NDI Discovery Server
- Support for Windows, Mac, and Custom NTP address
- Support for Variable Latency parameters of SRT
- Changed default OSD Timeout to “Off”
- Changed camera RTSP stream 2 output to “MJPEG” when NDI Preset is set to “Off” (This allows view of the camera feed within the Web Interface’s “Live” tab)
- DHCP bug fixes
12/15/2020 – SOC ver 6.3.11
- DHCP bug fixes
- Correct a network feed bug between stream 1 & stream 2 resolutions
7/14/2020 – SOC ver 6.3.04 (PoE)
- Improved audio line-in quality
- Added inquery command to retrieve camera lens type
- Bugfixes with anti-flicker
10/4/2019 – SOC ver 6.2.83 (PoE)
- Supports Multi-Language
- Supports RTMPS
- Photobooth Functionality
- Improved i-Frame range
- Improved Port range
- Supports New IR Remote IP Address Set shortcuts
- [#] + [*] + [#] + [1]: Sets IP Address to 192.168.100.81
- [#] + [*] + [#] + [2]: Sets IP Address to 192.168.100.82
- [#] + [*] + [#] + [3]: Sets IP Address to 192.168.100.83
- [#] + [*] + [#] + [4]: Sets IP Address to 192.168.100.84
- [#] + [*] + [#] + [5]: Sets IP Address to 192.168.100.85
- [#] + [*] + [#] + [6]: Sets IP Address to 192.168.100.86
- [#] + [*] + [#] + [7]: Sets IP Address to 192.168.100.87
- [#] + [*] + [#] + [8]: Sets IP Address to 192.168.100.88
- [#] + [*] + [#] + [9]: Sets IP Address to 192.168.100.89
- [#] + [*] + [#] + [0]: Sets IP Address to 192.168.100.80
5/22/2019 – SOC ver 6.2.71 (PoE)
- Remove assignable VISCA Addr in WebUI
- I/F Clear Command
- P/T Reset Command
- Web Server Security Update
- PTZ Motion Sync (Experimental)
- NTP synchronization
- Assignable UDP Port
- Broadcast Frame Rates (Experimental)
- PanTilt_LimitSet via VISCA over IP
- CORS
- HTTP-CGI Direct Zoom with Speed
- ONVIF Login Fix
- WEB S/N
- multicast default address 234.1.2.88
- presets being saved with the backup file
6/1/2018 – SOC 6.2.50 (PoE)
- Resolves camera reset from heavy network traffic
1/18/2018 – SOC ver 6.2.40
- NDI compatibility improvement
- Bug fixes
1/17/18 – SOC 6.2.23 (non-PoE)
- Camera is now “NDI Ready”
- Presets 1-9 include focus
- Video within web interface enabled in Internet Explorer (ActiveX driver needed from downloads page)
- Web interface now affects OSD Menu Settings
- New IR Remote shortcut for DHCP: [#]+[*]+[4]
- Removed “D-HotPixel” from Noise Reduction in OSD
- Added “Auto Scan Shoot” in OSD Menu
6/16/17 – SOC 6.2.23 (PoE & non-PoE)
- Improved performance with PT-JOY/PT-JOY-G2
- Bug fixes
PT20X-USB-xx
9/16/2021 – SOC ver 6.2.73
- Solved network feed audio issues
12/15/2020 – SOC ver 6.2.66
- General bugfixes and compatibility updates
- Added OSD Timeout to OSD menu within Settings
- DHCP bugfixes
- Framerate bugfixes
- Default Preset Recall Speed changed to 12 from 24
- Added support for focal range
- Added support for TFTP firmware upgrades
- Supports network feed image freeze (requires cam restart)
- Changed OSD default values
6/16/2020 – SOC ver 6.2.62
- UVC bugfixes
- PanTilt_LimitSet bugfix while mirrored
- Optimized auto focus
- Added automatic sharpness to OSD
- Added RG / BG Tuning to OSD
- Added more IR remote shortcuts
- [#] + [*] + [#] + [1]: Sets IP Address to 192.168.100.81
- [#] + [*] + [#] + [2]: Sets IP Address to 192.168.100.82
- [#] + [*] + [#] + [3]: Sets IP Address to 192.168.100.83
- [#] + [*] + [#] + [4]: Sets IP Address to 192.168.100.84
- [#] + [*] + [#] + [5]: Sets IP Address to 192.168.100.85
- [#] + [*] + [#] + [6]: Sets IP Address to 192.168.100.86
- [#] + [*] + [#] + [7]: Sets IP Address to 192.168.100.87
- [#] + [*] + [#] + [8]: Sets IP Address to 192.168.100.88
- [#] + [*] + [#] + [9]: Sets IP Address to 192.168.100.89
- [#] + [*] + [#] + [0]: Sets IP Address to 192.168.100.80
10/4/2019 – SOC ver 6.2.56
- Photobooth Functionality
- Support Serial Number through Web Interface
- Improved i-Frame range
- Improved Port range
- Supports RTSP password Authentication
- Supports RTMPS
- Corrected “Home” VISCA over IP command
5/22/2019 – SOC ver 6.2.48
- WebUI S/N
- NTP Synchronization
- Assignable UDP Port
- Remove assignable VISCA Addr in WebUI
- ONVIF Login Fix
- Multicast default address 234.1.2.88
- P/T Reset Command
- PTZ Motion Sync (Experimental)
- CORS
- HTTP-CGI Direct Zoom with Speed
- PanTilt_LimitSet via VISCA over IP
- I/F Clear Command
- Backup and Save As
- HOME position proper ack / response
- OSD Option & VISCA command to disable USB Audio
- 81 2a 02 a0 04 0p ff p=2: on, p=3: off
- 81 2a 02 a0 04 ff Query USB Audio
- 90 50 03 ff = off
- 90 50 02 ff = on
12/18/2017 – SOC ver 6.2.39
- Camera is now “NDI Ready”
- Presets 1-9 include focus
- Video within web interface enabled in Internet Explorer (ActiveX driver needed from downloads page)
- Web interface now affects OSD Menu Settings
- New IR Remote shortcut for DHCP: [#]+[*]+[4]
- Removed “D-HotPixel” from Noise Reduction in OSD
- Added “Auto Scan Shoot” in OSD Menu
6/16/2017 – SOC 6.2.23
- Improved performance with PT-JOY/PT-JOY-G2
- Bug fixes
PT30X-SDI/NDI-xx
6/21/2022 – SOC ver 6.3.32
- Added MIDI Control (For notes on how to configure MIDI Camera Control, read the MIDI Guide available here)
- Change the Max Bit Rate to 102,400 kbps
4/21/2022 – SOC ver 6.3.30
- Added the ability to save unique OSD settings per preset
- Added a VISCA over IP command to enable/disable RTMP streaming
- 81 0A 11 A8 pq FF – p: 1 Stream 1; p: 2 stream 2; q: 2 ON, q: 3 OFF
- Added a VISCA over IP command to enable/disable RTMP streaming
- Changed the default Device ID to “ptzoptics”
- Added support for a HTTPS certificate file
- NTP Time Zones now support half time zones
- SRT now supports domain name mode. Default is set to Off
- Changed 3DNR default value to “Auto”
- Added support for additional HTTP-CGI commands
- http://[camera ip]/cgi-bin/param.cgi?post_image_value&wbmode&[mode]
- [mode] options: auto, indoor, outdoor, onepush, manual, var, trigger
- http://[camera ip]/cgi-bin/param.cgi?post_image_value&aemode&[mode]
- [mode] options: auto, manual, shutter, iris, bright
- http://[camera ip]/cgi-bin/param.cgi?post_image_value&wbmode&[mode]
- Added a VISCA over IP command to Freeze/Unfreeze the video feed
- 81 01 04 62 0p FF – p: 2 ON; p: 3 OFF
- Updated the camera’s web interface & available options
- The camera’s Standby light will now be illuminated when it’s set to Standby mode via the VISCA over IP command
- Fixed a Zoom Speed bug
- Fixed a bug when viewing the web interface using Safari
6/29/2021 – SOC ver 6.3.20
- Bugfix: Fixed issue with IR remote panning/tilting
6/21/2021 – SOC ver 6.3.20
- Resolved a NDI upgrading issue
- Corrected the name the camera shows in Studio Monitor (Now correctly displays camera name & IP address)
- Resolved an issue with the Web Interface not showing the NDI Config tab
- Resolved issue with Direct Zoom command not zooming into the correct value (Any direct zoom command from 29x~30x [3FE1 ~ 4000] moves to the same position)
3/31/2021 – SOC ver 6.3.18 (PoE)
- Support for NDIv4|HX
- Support for NDI Discovery Server
- Support for Windows, Mac, and Custom NTP address
- Support for Variable Latency parameters of SRT
- Changed default OSD Timeout to “Off”
- Changed camera RTSP stream 2 output to “MJPEG” when NDI Preset is set to “Off” (This allows view of the camera feed within the Web Interface’s “Live” tab)
- DHCP bug fixes
12/15/2020 – SOC ver 6.3.12
- DHCP bug fixes
9/21/2020 – SOC ver 6.3.11
- Audio embedding over HDMI & RTSP issue resolved
- Stream 2 image flip issue resolved
- Added OSD Timeout to OSD Menu
6/16/2019 – SOC ver 6.2.85
- Image Freeze in OSD
- Assorted bugfixes
10/4/2019 – SOC ver 6.2.79
- Supports Multi-Language
- Supports RTMPS
- Photobooth Functionality
- Improved i-Frame range
- Supports New IR Remote IP Address Set shortcuts
- [#] + [*] + [#] + [1]: Sets IP Address to 192.168.100.81
- [#] + [*] + [#] + [2]: Sets IP Address to 192.168.100.82
- [#] + [*] + [#] + [3]: Sets IP Address to 192.168.100.83
- [#] + [*] + [#] + [4]: Sets IP Address to 192.168.100.84
- [#] + [*] + [#] + [5]: Sets IP Address to 192.168.100.85
- [#] + [*] + [#] + [6]: Sets IP Address to 192.168.100.86
- [#] + [*] + [#] + [7]: Sets IP Address to 192.168.100.87
- [#] + [*] + [#] + [8]: Sets IP Address to 192.168.100.88
- [#] + [*] + [#] + [9]: Sets IP Address to 192.168.100.89
- [#] + [*] + [#] + [0]: Sets IP Address to 192.168.100.80
5/22/2019 – SOC ver 7.2.73
- WebUI S/N
- NTP Synchronization
- Assignable UDP Port
- Remove assignable VISCA Addr in WebUI
- ONVIF Login Fix
- Web Server Security Update
- Multicast default address 234.1.2.88
- P/T Reset Command
- PTZ Motion Sync (Experimental)
- CORS
- HTTP-CGI Direct Zoom with Speed
- PanTilt_LimitSet via VISCA over IP
- I/F Clear Command
- Backup and Save As
- HOME position proper ack / response
5/30/2018 – SOC ver 6.2.50
- Resolves camera reset from heavy network traffic
4/8/2018 – SOC 6.2.46
- Improved NDI compatibility
- Bug fixes
PTVL-ZCAM/NDI-ZCAM
9/15/2021 – SOC ver 7.2.82
- Solved the issue on invalid IP address when using Backup & Restore function
4/29/2021 – SOC ver 7.2.79
- OSD Timeout is Off by default
- NTP to Web Interface
- SRT to Web Interface
- Corrected CAM_BrightPosInq command
- TFTP Upgrade
- Network audio fix
- NDI cameras now support NDIv4|HX
- NDI cameras now have NDI Config tab in Web Interface
- NDI cameras now support NDI Discovery Server
- NDI cameras now support NDIv4 Multicast
- NDI cameras now support NDIv4 control (very limited)
11/15/2019 – SOC ver 7.2.73
- Added VISCA Address Fix
- Corrected Sharpness Inquiry bug
- Added VISCA commands for adjusting Red/Blue Gain Tuning
- CAM_RTuning: 8x 0A 01 12 pq FF
- CAM_RTuningInq: 8x 09 04 12 FF – Response: 90 50 00 00 0p 0q FF
- CAM_BTuning: 8x 0A 01 13 pq FF
- CAM_BTuningInq: 8x 09 04 13 FF – Response: 90 50 00 00 0p 0q FF
- pq: 0x00 ~ 0x14
10/4/2019 – SOC ver 7.2.70
- Photobooth Functionality
- Supports Multi-language
- Supports RTMPS
5/22/2019 – SOC ver 7.2.67
- NTP synchronization
- Assignable UDP Port
- Web Server Security Update
- Hold Left on DPad to toggle DHCP / Static IP
- ONVIF Login Fix
- CORS
- Remove assignable VISCA Addr in WebUI
7/3/2018 – SOC ver 7.2.50
- Resolves camera reset from heavy network traffic
- Camera is now “NDI Ready”
2/1/2018 – SOC ver 7.2.41
- Camera is now “NDI Ready”
- Video within web interface enabled in Internet Explorer (ActiveX driver needed from downloads page)
- Web interface now affects OSD Menu Settings
- Removed “D-HotPixel” from Noise Reduction in OSD
PT12X-ZCAM/NDI-ZCAM
9/15/2021 – SOC ver 7.2.76
- Support TFTP upgrade
- OSD Timeout is Off by default
- NTP to Web Interface
- SRT to Web Interface
- Corrected CAM_BrightPosInq command
- NDI® cameras now support NDI®v4|HX
- NDI® cameras now have NDI® Config tab in Web Interface
- NDI® cameras now support NDI®v4 Multicast
- NDI® cameras now support NDI®v4 control
11/15/2019 – SOC ver 7.2.72
- Added VISCA Address Fix
- Corrected Sharpness Inquiry bug
- Added VISCA commands for adjusting Red/Blue Gain Tuning
- CAM_RTuning: 8x 0A 01 12 pq FF
- CAM_RTuningInq: 8x 09 04 12 FF – Response: 90 50 00 00 0p 0q FF
- CAM_BTuning: 8x 0A 01 13 pq FF
- CAM_BTuningInq: 8x 09 04 13 FF – Response: 90 50 00 00 0p 0q FF
- pq: 0x00 ~ 0x14
10/4/2019 – SOC ver 7.2.70
- Photobooth Functionality
- Supports Multi-language
- Supports RTMPS
5/22/2019 – SOC ver 7.2.67
- NTP synchronization
- Assignable UDP Port
- Web Server Security Update
- Hold Left on DPad to toggle DHCP / Static IP
- ONVIF Login Fix
- CORS
- Remove assignable VISCA Addr in WebUI
PT20X-ZCAM/NDI-ZCAM
9/15/2021 – SOC ver 7.2.82
- Support TFTP upgrade
- OSD Timeout is Off by default
- NTP to Web Interface
- SRT to Web Interface
- Corrected CAM_BrightPosInq command
- NDI® cameras now support NDI®v4|HX
- NDI® cameras now have NDI® Config tab in Web Interface
- NDI® cameras now support NDI®v4 Multicast
- NDI® cameras now support NDI®v4 control
11/15/2019 – SOC ver 7.2.73
- Added VISCA Address Fix
- Corrected Sharpness Inquiry bug
- Added VISCA commands for adjusting Red/Blue Gain Tuning
- CAM_RTuning: 8x 0A 01 12 pq FF
- CAM_RTuningInq: 8x 09 04 12 FF – Response: 90 50 00 00 0p 0q FF
- CAM_BTuning: 8x 0A 01 13 pq FF
- CAM_BTuningInq: 8x 09 04 13 FF – Response: 90 50 00 00 0p 0q FF
- pq: 0x00 ~ 0x14
10/4/2019 – SOC ver 7.2.70
- Photobooth Functionality
- Supports Multi-language
- Supports RTMPS
5/22/2019 – SOC ver 7.2.67
- NTP synchronization
- Assignable UDP Port
- Web Server Security Update
- Hold Left on DPad to toggle DHCP / Static IP
- ONVIF Login Fix
- CORS
- Remove assignable VISCA Addr in WebUI
6/29/2018 – SOC ver 7.2.50
- Resolves camera reset from heavy network traffic
- Camera is now “NDI Ready”
2/1/2018 – SOC ver 7.2.41
- Camera is now “NDI Ready”
- Presets 1-9 include focus
- Video within web interface enabled in Internet Explorer (ActiveX driver needed from downloads page)
- Web interface now affects OSD Menu Settings
- Removed “D-HotPixel” from Noise Reduction in OSD
PTEPTZ-ZCAM/NDI-ZCAM
9/15/2021 – SOC ver 8.1.82
- Solved the issue on invalid IP address when using Backup & Restore function
4/29/2021 – SOC ver 8.1.81
- OSD Timeout is Off by default
- NTP to Web Interface
- SRT to Web Interface
- Corrected CAM_BrightPosInq command
- TFTP Upgrade
- Network audio fix
- NDI cameras now support NDIv4|HX
- NDI cameras now have NDI Config tab in Web Interface
- NDI cameras now support NDI Discovery Server
- NDI cameras now support NDIv4 Multicast
- NDI cameras now support NDIv4 control
- NDI Preset set to Ultra by default
- Added VISCA over IP command CAM_NetworkReset
- 81 0A 01 AA FF
- NDI cameras now output 2) NDIv4|HX feeds simultaneously (EPTZ & Ref)
PT-WEBCAM-80
11/30/2020 – SOC ver 1.3.19
- Added compatibility with Webcam Config Tool
7/14/2020 – SOC ver 1.3.10
- Mac audio bugfix
- EPTZ bugfixes
12/4/2019 – SOC ver 1.2.70
- Added OSD option to disable microphone
- Fixed issue with opening OSD within WebRTC
- Fixed image mirror issue
PT-JOY-G4
9/23/2021 – SOC ver 4.0.3 2021_09_22
- Added Gain to the Iris / Shutter dial. (Now Iris > Shutter > Gain respectively) (Only available in Manual Exposure)
PT-SUPERJOY-G1
8/3/2022 – SOC ver 2.1.7
- Added Network Time Protocol (NTP) to web interface.
- Added ability to send HTTP-CGI Custom Button toggles.
- First press sends one string of commands. Second press sends a second string of commands.
- Bugfix: USB port didn’t allow for firmware updates every time.
1/5/2022 – SOC ver 2.0.7-211217
- Added the MAC address to the Settings > Network page.
- Added the ability to use special characters in the password (!@#$%^&*).
- Added the ability to NDI Search for multiple sources under a single IP address.
- Added the ability to assign Pan/Tilt/ Zoom/Focus speeds per camera.
- Added the ability to disable Pan/Tilt /Zoom/Focus.
- Fixed issue with Focus dial not being affected by Focus Speed buttons.
- Fixed issue with HTTP-CGI Custom Buttons requiring certain characters.
10/29/2021 – SOC ver 2.0.6-211022
- Added the ability to send HTTP-CGI commands to the SuperJoy
- Added the ability to change the anti-flicker of the HDMI output (50Hz / 60Hz)
- Added Gain control to the Iris/Shutter dial. (Now Iris/Shutter/Gain)
- Iris = Blue, Shutter = Red, Gain = Purple
- Current models only have the text “Iris/Shutter”. Future models (no ETA yet) will have the full “Iris/Shutter/Gain”
- Added Dynamic DNS function to the web interface
- Added the ability to search for PTZOptics and NDI cameras on the network from the web interface
- Added the ability to change the web port of the SuperJoy in the web interface
9/3/2021 – SOC ver 2.0.5-210902
- HDMI Output bugfix: SuperJoys with Serial Number 20210601#### and beyond would lose the HDMI Output functionality after applying the 2.0.4-210430 firmware. The 2.0.5-210902 firmware restores the HDMI Output functionality.